Sep 7โ€‰โ€“โ€‰11, 2026
Buenos Aires, Argentina
America/Argentina/Buenos_Aires timezone

Session

POSTER SESSION

Sep 9, 2026, 2:00โ€ฏPM
Buenos Aires, Argentina

Buenos Aires, Argentina

IFIByNE (CONICET-UBA) - Intendente Gรผiraldes 300 Buenos Aires Autonomous City of Buenos Aires

Presentation materials

There are no materials yet.

  1. 9/9/26, 2:00โ€ฏPM
    Mechanical structures
    Poster Presentation

    The bulk insert is a key shielding-penetration component in the CSNS-II project. Its inner end faces directly toward the target center, while its outer end connects to the external environment; consequently, the neutron guide housed within the bulk insert cannot be locally adjusted near the target side. Thus, the design of the adjustment mechanism for the bulk insert is critical for ensuring...

    Go to contribution page
  2. Wenting Du (Institute of High Energy Physics, CAS)
    9/9/26, 2:00โ€ฏPM
    Instrument design and construction
    Poster Presentation

    The first horizontal-geometry liquid neutron reflectometer (LNR) of China is now being constructed in China Spallation Neutron Source (CSNS), which is designed to complement the existing vertical-geometry reflectometer and address the urgent demand for in-situ characterization of gas-liquid, liquid-liquid, and solid-liquid interface structures in colloid chemistry, biomedicine, advanced...

    Go to contribution page
  3. Adrian Nyc (Jรผlich Centre for Neutron Science JCNS, Forschungszentrum Jรผlich, Garching, Germany)
    9/9/26, 2:00โ€ฏPM
    Instrument design and construction
    Poster Presentation

    An important area of fundamental research with neutrons is the investigation of magnetic materials. Spherical neutron polarimetry (SPN) can be used. For this, a spin-polarized neutron beam is used, which hits the sample and the scattered intensity is then measured with detectors. In order to adiabatically rotate the polarity of the neutron beam in the required direction, a rotatable magnetic...

    Go to contribution page
  4. Daniel Zahreddin (TUM FRM II)
    9/9/26, 2:10โ€ฏPM
    Shielding
    Poster Presentation

    The cold triple-axis spectrometer (TAS) FLEXX at HZB was a highly successful instrument that underwent several upgrades during its operation [1โ€“4]. Preserving its capabilities for the neutron scattering community has been a major motivation for the development of the new LaDiff instrument at MLZ. In particular, LaDiff addresses the current lack of Larmor diffraction (LD) [5โ€“6] and, as a...

    Go to contribution page
  5. Doug Johnson (NIST Center for Neutron Research)
    9/9/26, 2:10โ€ฏPM
    Project management
    Poster Presentation

    Problem
    At the NCNR we have encountered issues during instrument installations and maintenance where it would have been beneficial to obtain firsthand knowledge on how an engineering technician would perform a task. Topics such as specific tooling, rigging for lifting, order of assembly, access for maintenance etc. Consulting with technicians during design reviews provides valuable...

    Go to contribution page
  6. Manuel Mรผller (Forschungs-Neutronenquelle Heinz Maier Leibnitz (FRM II))
    9/9/26, 2:10โ€ฏPM
    Mechanical structures
    Poster Presentation

    For polarization analysis experiments at the cold neutron triple-axis spectrometer KOMPASS, a precisely aligned magnetic field of up to 20 x 10-4 T is required, generated by a specialized Helmholtz coil system. To prevent reflection interference of the neutron beam at the coil segments, a custom-designed, non-magnetic, low-profile rotary platform was developed.

    During initial testing of...

    Go to contribution page
  7. Ed Binkley (NIST Center for Neutron Research)
    9/9/26, 2:20โ€ฏPM
    Instrument design and construction
    Poster Presentation

    The NCNR has upgraded and added new capabilities to the Diffractometer for Texture and Residual Stress (DARTS) The purpose of the instrument is to non-destructively measure tri-axial residual stresses in industrial parts and structural materials at spatial resolutions ๏‚ณ 1 mm3. Stresses are determined from the measurement of elastic changes in the interatomic lattice spacing at depths up to...

    Go to contribution page
  8. Luca Sagliano (European Spallation Source)
    9/9/26, 2:20โ€ฏPM
    Mechanical structures
    Poster Presentation

    Understanding the behaviour of engineering materials under complex loading conditions requires experimental systems capable of reproducing realistic mechanical states while allowing the evolution of internal features to be investigated. Neutron imaging and diffraction are powerful complementary techniques for studying deformation, strain development, and damage mechanisms in bulk materials....

    Go to contribution page
  9. Christian Fuchs (MLZ Research Neutron Source FRM II)
    9/9/26, 2:20โ€ฏPM
    Instrument design and construction
    Poster Presentation

    The TIGER project comprises the development, construction, and commissioning of the world's first thermal MIEZE spin-echo option at the resonant neutron spin-echo spectrometer RESEDA. Its objective is to extend the accessible parameter range of RESEDA towards higher momentum and energy transfers while maintaining the highest energy resolution through the additional use of thermal neutrons with...

    Go to contribution page
  10. Antoine Lepine (European Spallation Source ERIC)
    9/9/26, 2:30โ€ฏPM
    Detectors
    Poster Presentation

    The CSPEC instrument at the European Spallation Source (ESS) uses 12 large-area 3He detectors that will require evacuation, filling, and occasional gas recovery throughout their lifetime. To handle the detector gases while minimizing the loss 3He, a dedicated mobile gas transfer system was developed.

    The design is based on an existing gas transfer bench developed at the Institut...

    Go to contribution page
  11. Mr Felix Maciel (CNEA)
    9/9/26, 2:30โ€ฏPM
    Control systems
    Poster Presentation

    Abstract
    This poster describes progress in the implementation of distributed control systems and metrological validation for parts of neutron beam instruments at the Argentine Neutron Beam Laboratory (LAHN). Within the framework of the ANDES (Advanced Neutron Diffractometer for Engineering & Science) project, a control scheme based on the Tango Controls paradigm was developed, using the...

    Go to contribution page
  12. Yongjin Kim (FRM II)
    9/9/26, 2:30โ€ฏPM
    Instrument design and construction
    Poster Presentation

    PUMA is the thermal neutron three axes spectrometer (TAS) at MLZ, which is co-operated by the Institute of Quantum Materials and Technologies of the Karlsruhe Institute of Technology (IQMT, KIT) and the Technical University of Munich (TUM). Owing to the dynamical double-focusing technique and compact neutron optics with wide beam divergence, PUMA is mainly characterized as one of the highest...

    Go to contribution page
  13. Ryota Komine (J-PARC MLF)
    9/9/26, 2:40โ€ฏPM
    Turning machines (choppers, NVS)
    Poster Presentation

    In the Material and Life Science Experimental Facility (MLF) at J-PARC, six T0 choppers are operated on JAEA instruments. These choppers have been in operation for over ten years since their installation, and to enhance functionality, we have developed a second-generation T0 chopper. Since the first-generation, Inconel X750โ€”a nickel-based alloyโ€”has been used for the hammer material. However,...

    Go to contribution page
  14. Derek Doane (Oak Ridge National Laboratory (Spallation Neutron Source))
    9/9/26, 2:40โ€ฏPM
    Mechanical structures
    Poster Presentation

    This poster will present the precision measurement and alignment capabilities of the Survey, Alignment, and Metrology Group at the Spallation Neutron Source (SNS). Our team provides high accuracy geometric characterization across both accelerator systems and neutron beamlines, supporting reliable operations and enabling consistently high quality neutron production. Core activities include...

    Go to contribution page
  15. Fernando Ariel Sรกnchez (COMISION NACIONAL DE ENERGIA ATOMICA)
    9/9/26, 2:40โ€ฏPM
    Shielding
    Poster Presentation

    A new instrument for Prompt Gamma Neutron Activation Analysis (PGNAA) has been installed at the RA-6 (1 MW) research and training reactor located at the Bariloche Atomic Centre (San Carlos de Bariloche, Argentina). This non-destructive elemental analysis technique enables the determination of major components and is particularly useful for quantifying B, Cd, Sm and Gd at trace levels, as well...

    Go to contribution page
  16. Luiz Paulo de Oliveira (Reator Multipropรณsito Brasileiro - CNEN)
    9/9/26, 2:50โ€ฏPM
    Instrument design and construction
    Poster Presentation

    In this work, we present the design of the neutron collimation system for the high-resolution neutron powder diffractometer at IPEN/CNEN, named BรŽAR (Brazilian Instrument of Adjustable Resolution). The IEA-R1 reactor is a 5 MW light-water-moderated research reactor located at the Institute for Energy and Nuclear Research (IPEN) in Sรฃo Paulo, Brazil. The design of the collimation system...

    Go to contribution page
  17. Scott Olsen (Australian Nuclear Science and Technology Organisation)
    9/9/26, 2:50โ€ฏPM
    Mechanical structures
    Poster Presentation

    The Inelastic Neutron Time of Flight Instrument Pelican began operating in 2014. The instrument has a high intensity and high resolution master fermi chopper. Due to space constraints and shielding designs the time to change between the choppers is over half a day. As a result this change is very rarely undertaken.

    A new optical bench design is underway in which a translation system will...

    Go to contribution page
  18. Alexandre Souza (Instituto de Pesquisas Energรฉticas e Nucleares)
    9/9/26, 2:50โ€ฏPM
    Instrument design and construction
    Poster Presentation

    Alexandre P.S. Souza1,2, Carlos G.S. Silva1,2, Frederico A. Genezini1,2
    1Reator Multipropรณsito Brasileiro (RMB), Comissรฃo Nacional de Energia Nuclear (CNEN),
    Sรฃo Paulo โ€“ Brazil.
    2Instituto de Pesquisas Energรฉticas e Nucleares (IPEN), Comissรฃo Nacional de Energia Nuclear (CNEN), Sรฃo Paulo โ€“ Brazil.
    alexandre.s-fpatria@ipen.br
    In this work, we present the first high-fidelity Monte Carlo...

    Go to contribution page
  19. Peter Zabala Medina (Laboratorio Argentino de Haces de Neutrones (LAHN), Comisiรณn Nacional de Energรญa Atรณmica (CNEA))
    9/9/26, 3:00โ€ฏPM
    Instrument design and construction
    Poster Presentation

    Scintillator-camera detector systems are widely used in neutron radiography and tomography, yet geometric distortions and field-dependent effects are seldom characterized within a rigorous metrological framework. Uncorrected distortions can propagate into reconstructed volumes, introducing systematic dimensional bias and spatial non-uniformities that limit quantitative reliability and...

    Go to contribution page
  20. Dr Luis Alberto Rodrรญguez Palomino (CNEA-CONICET-UTN)
    9/9/26, 3:00โ€ฏPM
    Instrument design and construction
    Poster Presentation

    The NAHUEL instrument (Neutrones para Anรกlisis de Haces en Usos de Espectrometrรญa en Longitud de Onda) is the first time-of-flight (TOF) neutron instrument to operate at an Argentine research reactor.ย Recently commissioned at the RA-6 reactor at the Bariloche Atomic Centre, Argentina, NAHUEL supports both fundamental and applied research in nuclear engineering and related technologies. In this...

    Go to contribution page
  21. Dr Jay T. Cremer (Adelphi Technology Inc.)
    9/9/26, 3:00โ€ฏPM
    Neutron optics
    Poster Presentation

    Engineering diffractometers at reactor neutron sources typically use monochromatic beams and scan detectors through 2ฮธ to measure selected Bragg reflections. Because the scattering angle varies among reflections, this geometry can produce asymmetric, reflection-dependent gauge volumes. In contrast, time-of-flight engineering diffractometers commonly use detector banks fixed near 90ยฐ, providing...

    Go to contribution page
  22. Scott Olsen (Australian Nuclear Science and Technology Organisation)
    9/9/26, 3:10โ€ฏPM
    Instrument design and construction
    Poster Presentation

    This submission presents the process and outcome for the development of an optimised neutron beam slit aperture assembly. The Australian Centre for Neutron Scattering (ACNS) utilises slit assemblies to limit and shape neutron flow along the beamlines in the facility. Minimising the linear footprint and simplifying the operation of these assemblies allows additional equipment and/or...

    Go to contribution page
  23. Fernando Pschunder (LAHN-CNEA)
    9/9/26, 3:10โ€ฏPM
    Instrument design and construction
    Poster Presentation

    El Laboratorio Argentino de Haces de Neutrones (LAHN) constituye un centro nacional de referencia para la caracterizaciรณn de materiales mediante tรฉcnicas neutrรณnicas de รบltima generaciรณn. Sus instrumentos aprovecharรกn las fuentes tรฉrmica y frรญa del reactor RA-10, actualmente en fase final de construcciรณn en el Centro Atรณmico Ezeiza (Buenos Aires, Argentina). Las facilidades experimentales...

    Go to contribution page
  24. Alejandro Said Nรบรฑez Selin (CNEA)
    9/9/26, 3:10โ€ฏPM
    Detectors
    Poster Presentation

    Water Cherenkov detectors (WCDs) offer a robust and economical solution for real time radiation monitoring by detecting Cherenkov light from charged particles moving faster than light in water. This work presents a novel two stage classification framework for gamma-neutron discrimination: an initial physics based energy threshold filters unambiguous low energy gamma sources, followed by a...

    Go to contribution page
  25. Mr Emanuel Adriรกn (CNEA)
    9/9/26, 3:20โ€ฏPM
    Mechanical structures
    Poster Presentation

    The Laboratorio Argentino de Haces de Neutrones (LAHN) is currently developing the ANDES (Advanced Diffractometer for Engineering and Science) neutron instrument for the Reactor RA-10. The instrument requires the highly accurate positioning and displacement of its subsystems over a specially designed sliding floor. These operational requirements impose stringent design specifications on the...

    Go to contribution page
  26. Diego G. Franco (CNEA-CONICET)
    9/9/26, 3:20โ€ฏPM
    Instrument design and construction
    Poster Presentation

    We are currently developing a high-resolution powder diffractometer for the GT1 beamline of the RA-10 multipurpose research reactor at the Argentine Laboratory for Neutron Beams (LAHN). The optimization of the instrument neutron optics requires realistic simulations capable of reproducing the spatial, angular, and chromatic distributions of the incident neutron beam.
    In this work, we present...

    Go to contribution page
  27. Tamires Gallo (European Spallation Source)
    9/9/26, 3:20โ€ฏPM
    Project management
    Poster Presentation

    This study presents preliminary findings from an applied mixedโ€‘methods investigation into how stakeholder management practices influence the alignment between planning and execution in international scientific megaprojects developed through Inโ€‘Kind Contributions (IKC). IKCโ€‘based projects operate within distributed governance structures, multiโ€‘institutional interfaces, and heterogeneous...

    Go to contribution page
  28. Lucas Mariano Montenegro (Centro de Investigaciรณn Laboratorio Argentino de Haces de Neutrones (LAHN), Comisiรณn Nacional de Energรญa Atรณmica (CNEA), Buenos Aires, Argentina)
    9/9/26, 3:20โ€ฏPM
    Mechanical structures
    Poster Presentation

    The design of highly controlled sample environments is a critical engineering challenge for the successful operation of modern neutron scattering facilities. The Argentine Neutron Beam Laboratory (LAHN), currently under construction, will host the Advanced Neutron Diffractometer for Engineering and Science (ANDES). This instrument is designed to characterize the crystallographic structures of...

    Go to contribution page
Building timetable...